Urban gas enterprises are different in management due to different regions and cultures. With the development of science and technology and the Internet, new equipment and technology are gradually combined with natural gas metering management. However, due to the incomplete development of this field in China, there is still a lot of room for progress, especially at the level of specific enterprises. At present, the metering management of many enterprises is still in the same stage At the primary stage, this paper focuses on the analysis of the causes of gas transmission difference, through observation and experiment, to find out the solutions with strong operability, and to provide valuable reference for enterprises to strengthen the management of gas transmission difference. At the beginning of this paper, the author points out the significance of the research on the measurement and transmission difference of natural gas, and then analyzes the causes of the measurement and transmission difference of natural gas through practical cases combined with historical research and experimental data. The best way is to explore the causes of the measurement and transmission difference of various types of natural gas and summarize the effective methods to reduce the measurement and transmission difference of natural gas.

Published in International Journal of Energy and Power Engineering (Volume 8, Issue 6)
DOI 10.11648/j.ijepe.20190806.14
Page(s) 94-99
Creative Commons

This is an Open Access article, distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution and reproduction in any medium or format, provided the original work is properly cited.

Copyright

Copyright © The Author(s), 2019. Published by Science Publishing Group

Keywords

Transmission Difference, Urban Gas Enterprises, Temperature Sensor

References
[1] Liang Xiang. Discussions on the relevant measures to implement the differential management in urban gas management [J]. Low Carbon World, 2019, 9 (04): 123-124.
[2] Jingru Liu. Causes and control of poor natural gas transmission [J]. Chemical design communication, 2019, 45 (08): 54 + 56.
[3] Qingjuan Guo. Measures to strengthen the management of gas transmission difference in pipelines [J]. Modern economic information, 2019 (10): 390.
[4] Bin Guo. Research on the Construction of Urban Gas Transmission and Distribution Pipeline Network [J]. Scientific and Technological Innovation and Application, 2019 (07): 86-87.
[5] Dongsheng Peng. Safety Management of Urban Gas Transmission and Distribution System [J]. Science and Technology Economic Guide, 2018, 26 (15): 234.
[6] Xu Zhao. Talking about how to strengthen the dispatching management of urban gas transmission and distribution [J]. Sichuan Cement, 2017 (12): 197.
[7] Hui Xiang. Cause analysis and Countermeasures of gas meter metering transmission difference [J]. Science and technology innovation, 2019 (14): 174-175.
[8] Yuan Gao. Application of Intelligent Technology in Urban Gas Transmission and Distribution Pipeline System [D]. Beijing University of Architecture, 2017.
[9] Yancong Liu. Discussion on Some Problems of Urban Gas Transmission and Distribution Pipeline Network [J]. Shanxi Science and Technology, 2017, 33 (03): 123-125.
[10] Feng Cheng. Analysis and Management of Urban Gas Transmission Difference [J]. Urban Gas, 2016 (07): 40-43.
[11] Guoping Gu. Problems and Countermeasures of gas transmission gap [J]. Scientific and technological innovation and application, 2015 (23): 150.
[12] Jing Zhang. Analysis of the causes and control points of gas transmission difference [J]. Research on modern state-owned enterprises, 2018 (12): 129 + 41.
[13] Jin Xu. Problems and control analysis of urban gas transmission gap [J]. China Management Informatization, 2015, 18 (14): 103.
[14] Shiyi Yang. Research on metering and transmission difference control of urban gas pipeline network [D]. Southwest Petroleum University, 2015.
[15] Saipeng Qi. Brief analysis of formation factors and control strategies of urban gas transmission gap [J]. Chemical Industry Management, 2014 (08): 150.
[16] Lisa Liao. Measures for Implementing Transport Difference Management in Urban Gas Management [J]. Enterprise Reform and Management, 2016 (18): 209.
Cite This Article
  • APA Style

    Zijian Zheng. (2019). Study on Causes and Control for the Transmission Difference of Urban Gas Enterprises. International Journal of Energy and Power Engineering, 8(6), 94-99. https://doi.org/10.11648/j.ijepe.20190806.14

    Copy | Download

    ACS Style

    Zijian Zheng. Study on Causes and Control for the Transmission Difference of Urban Gas Enterprises. Int. J. Energy Power Eng. 2019, 8(6), 94-99. doi: 10.11648/j.ijepe.20190806.14

    Copy | Download

    AMA Style

    Zijian Zheng. Study on Causes and Control for the Transmission Difference of Urban Gas Enterprises. Int J Energy Power Eng. 2019;8(6):94-99. doi: 10.11648/j.ijepe.20190806.14

    Copy | Download

  • @article{10.11648/j.ijepe.20190806.14,
      author = {Zijian Zheng},
      title = {Study on Causes and Control for the Transmission Difference of Urban Gas Enterprises},
      journal = {International Journal of Energy and Power Engineering},
      volume = {8},
      number = {6},
      pages = {94-99},
      doi = {10.11648/j.ijepe.20190806.14},
      url = {https://doi.org/10.11648/j.ijepe.20190806.14},
      eprint = {https://article.sciencepublishinggroup.com/pdf/10.11648.j.ijepe.20190806.14},
      abstract = {Urban gas enterprises are different in management due to different regions and cultures. With the development of science and technology and the Internet, new equipment and technology are gradually combined with natural gas metering management. However, due to the incomplete development of this field in China, there is still a lot of room for progress, especially at the level of specific enterprises. At present, the metering management of many enterprises is still in the same stage At the primary stage, this paper focuses on the analysis of the causes of gas transmission difference, through observation and experiment, to find out the solutions with strong operability, and to provide valuable reference for enterprises to strengthen the management of gas transmission difference. At the beginning of this paper, the author points out the significance of the research on the measurement and transmission difference of natural gas, and then analyzes the causes of the measurement and transmission difference of natural gas through practical cases combined with historical research and experimental data. The best way is to explore the causes of the measurement and transmission difference of various types of natural gas and summarize the effective methods to reduce the measurement and transmission difference of natural gas.},
     year = {2019}
    }
    

    Copy | Download

  • TY  - JOUR
    T1  - Study on Causes and Control for the Transmission Difference of Urban Gas Enterprises
    AU  - Zijian Zheng
    Y1  - 2019/12/26
    PY  - 2019
    N1  - https://doi.org/10.11648/j.ijepe.20190806.14
    DO  - 10.11648/j.ijepe.20190806.14
    T2  - International Journal of Energy and Power Engineering
    JF  - International Journal of Energy and Power Engineering
    JO  - International Journal of Energy and Power Engineering
    SP  - 94
    EP  - 99
    PB  - Science Publishing Group
    SN  - 2326-960X
    UR  - https://doi.org/10.11648/j.ijepe.20190806.14
    AB  - Urban gas enterprises are different in management due to different regions and cultures. With the development of science and technology and the Internet, new equipment and technology are gradually combined with natural gas metering management. However, due to the incomplete development of this field in China, there is still a lot of room for progress, especially at the level of specific enterprises. At present, the metering management of many enterprises is still in the same stage At the primary stage, this paper focuses on the analysis of the causes of gas transmission difference, through observation and experiment, to find out the solutions with strong operability, and to provide valuable reference for enterprises to strengthen the management of gas transmission difference. At the beginning of this paper, the author points out the significance of the research on the measurement and transmission difference of natural gas, and then analyzes the causes of the measurement and transmission difference of natural gas through practical cases combined with historical research and experimental data. The best way is to explore the causes of the measurement and transmission difference of various types of natural gas and summarize the effective methods to reduce the measurement and transmission difference of natural gas.
    VL  - 8
    IS  - 6
    ER  - 

    Copy | Download

Author Information
  • Nanjing Jinsheng Gas Equipment Co., Ltd., Nanjing, China

  • Sections