Aim Compared with the traditional position, we tried to explore the application of improved position for lower limb DR radiograph in hip and knee arthroplasty. Method Retrospective analysis of the traditional and improved DR radiographs from 60 cases for hip and knee arthroplasty, by comparing the division angle, lower limb mechanical axis length, mechanical deviation between the lower limb mechanical axis and the center of the tibial plateau. Results (1) Preoperative data from twenty cases of improved and 15 cases of traditional lower limb DR radiographs showed the mechanical deviations between the lower limb mechanical axis and the center of the tibial plateau were 28.18, 4.71, 30.66, 11.92; postoperative data from fifty cases of improved and 33 cases of traditional DR radiographs showed the mechanical deviations between the lower limb mechanical axis and the center of the tibial plateau were 5.04, 11.03 (P < 0.05). (2) Improved position much more clearly showed the full length of the lower limb, compared with traditional position. (3) Values preoperative correction angle of 31 cases of improved and 19 cases of traditional position were 5.9°, 6.7° (P < 0.05). Conclusion DR radiographs of improved position can realistically show the pre- and post-operative status of hip and knee. The data of correction angle, lower limb mechanical axis length, mechanical deviations between the lower limb mechanical axis and the center of the tibial plateau can be more accurate. It is more convenient for the selection of operation procedure and for the assessment of surgery and rehabilitation.
Published in | Journal of Surgery (Volume 6, Issue 2) |
DOI | 10.11648/j.js.20180602.11 |
Page(s) | 33-35 |
Creative Commons |
This is an Open Access article, distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution and reproduction in any medium or format, provided the original work is properly cited. |
Copyright |
Copyright © The Author(s), 2018. Published by Science Publishing Group |
Arthroplasty, DR Radiograph, Lower Limb Full Length, Traditional Body Position, Improved Body Position
[1] | M. B. Siqueira, D. Ramanathan, A. K. Klika, C. A. Higuera, W. K. Barsoum, Role of negative pressure wound therapy in total hip and knee arthroplasty, World J Orthop, 2016, (7): 30-37. |
[2] | S. R. Piedade, A. Pinaroli, E. Servien, P. Neyret, Revision after early aseptic failures in primary total knee arthroplasty, Knee Surg Sports Traumatol Arthrosc, 2009, (17): 248-253. |
[3] | T. K. Fehring, S. Odum, W. L. Griffin, J. B. Mason, M. Nadaud, Early failures in total knee arthroplasty, Clin Orthop Relat Res, 2001, DOI: 315-318. |
[4] | T. O. White, T. W. Dougall, Arthroplasty of the hip. Leg length is not important, J Bone Joint Surg Br, 2002, (84): 335-338. |
[5] | S. C. Tipton, J. K. Sutherland, R. Schwarzkopf, The Assessment of Limb Length Discrepancy Before Total Hip Arthroplasty, J Arthroplasty, 2016, (31): 888-892. |
[6] | G. Meermans, A. Malik, J. Witt, F. Haddad, Preoperative radiographic assessment of limb-length discrepancy in total hip arthroplasty, Clin Orthop Relat Res, 2011, (469): 1677-1682. |
[7] | A. Konyves, G. C. Bannister, The importance of leg length discrepancy after total hip arthroplasty, J Bone Joint Surg Br, 2005, (87): 155-157. |
[8] | Y. Zhang, W. He, T. Cheng, X. Zhang, Total Hip Arthroplasty: Leg Length Discrepancy Affects Functional Outcomes and Patient's Gait, Cell Biochem Biophys, 2015, (72): 215-219. |
[9] | M. R. Whitehouse, N. S. Stefanovich-Lawbuary, L. R. Brunton, A. W. Blom, The impact of leg length discrepancy on patient satisfaction and functional outcome following total hip arthroplasty, J Arthroplasty, 2013, (28): 1408-1414. |
[10] | S. P. Krishnan, R. W. Carrington, S. Mohiyaddin, N. Garlick, Common misconceptions of normal hip joint relations on pelvic radiographs, J Arthroplasty, 2006, (21): 409-412. |
APA Style
Huige Hou, Jinguo Lai, Xiufang Yan, Zhichao Lin. (2018). The Application of Improved Position for Lower Limb full Length DR Radiograph in Hip/Knee Arthroplasty. Journal of Surgery, 6(2), 33-35. https://doi.org/10.11648/j.js.20180602.11
ACS Style
Huige Hou; Jinguo Lai; Xiufang Yan; Zhichao Lin. The Application of Improved Position for Lower Limb full Length DR Radiograph in Hip/Knee Arthroplasty. J. Surg. 2018, 6(2), 33-35. doi: 10.11648/j.js.20180602.11
AMA Style
Huige Hou, Jinguo Lai, Xiufang Yan, Zhichao Lin. The Application of Improved Position for Lower Limb full Length DR Radiograph in Hip/Knee Arthroplasty. J Surg. 2018;6(2):33-35. doi: 10.11648/j.js.20180602.11
@article{10.11648/j.js.20180602.11, author = {Huige Hou and Jinguo Lai and Xiufang Yan and Zhichao Lin}, title = {The Application of Improved Position for Lower Limb full Length DR Radiograph in Hip/Knee Arthroplasty}, journal = {Journal of Surgery}, volume = {6}, number = {2}, pages = {33-35}, doi = {10.11648/j.js.20180602.11}, url = {https://doi.org/10.11648/j.js.20180602.11}, eprint = {https://article.sciencepublishinggroup.com/pdf/10.11648.j.js.20180602.11}, abstract = {Aim Compared with the traditional position, we tried to explore the application of improved position for lower limb DR radiograph in hip and knee arthroplasty. Method Retrospective analysis of the traditional and improved DR radiographs from 60 cases for hip and knee arthroplasty, by comparing the division angle, lower limb mechanical axis length, mechanical deviation between the lower limb mechanical axis and the center of the tibial plateau. Results (1) Preoperative data from twenty cases of improved and 15 cases of traditional lower limb DR radiographs showed the mechanical deviations between the lower limb mechanical axis and the center of the tibial plateau were 28.18, 4.71, 30.66, 11.92; postoperative data from fifty cases of improved and 33 cases of traditional DR radiographs showed the mechanical deviations between the lower limb mechanical axis and the center of the tibial plateau were 5.04, 11.03 (P Conclusion DR radiographs of improved position can realistically show the pre- and post-operative status of hip and knee. The data of correction angle, lower limb mechanical axis length, mechanical deviations between the lower limb mechanical axis and the center of the tibial plateau can be more accurate. It is more convenient for the selection of operation procedure and for the assessment of surgery and rehabilitation.}, year = {2018} }
TY - JOUR T1 - The Application of Improved Position for Lower Limb full Length DR Radiograph in Hip/Knee Arthroplasty AU - Huige Hou AU - Jinguo Lai AU - Xiufang Yan AU - Zhichao Lin Y1 - 2018/03/15 PY - 2018 N1 - https://doi.org/10.11648/j.js.20180602.11 DO - 10.11648/j.js.20180602.11 T2 - Journal of Surgery JF - Journal of Surgery JO - Journal of Surgery SP - 33 EP - 35 PB - Science Publishing Group SN - 2330-0930 UR - https://doi.org/10.11648/j.js.20180602.11 AB - Aim Compared with the traditional position, we tried to explore the application of improved position for lower limb DR radiograph in hip and knee arthroplasty. Method Retrospective analysis of the traditional and improved DR radiographs from 60 cases for hip and knee arthroplasty, by comparing the division angle, lower limb mechanical axis length, mechanical deviation between the lower limb mechanical axis and the center of the tibial plateau. Results (1) Preoperative data from twenty cases of improved and 15 cases of traditional lower limb DR radiographs showed the mechanical deviations between the lower limb mechanical axis and the center of the tibial plateau were 28.18, 4.71, 30.66, 11.92; postoperative data from fifty cases of improved and 33 cases of traditional DR radiographs showed the mechanical deviations between the lower limb mechanical axis and the center of the tibial plateau were 5.04, 11.03 (P Conclusion DR radiographs of improved position can realistically show the pre- and post-operative status of hip and knee. The data of correction angle, lower limb mechanical axis length, mechanical deviations between the lower limb mechanical axis and the center of the tibial plateau can be more accurate. It is more convenient for the selection of operation procedure and for the assessment of surgery and rehabilitation. VL - 6 IS - 2 ER -